Model | B12M2000-1 | B12M2000-2 | B24M2000-1 | B24M2000-2 | B48M2000-1 | B48M2000-2 |
Rated Power | 2000W | |||||
Peak Power | 4000W | |||||
Wave Form | Modified Sine Wave | |||||
Frequency | 50HZ/60HZ | |||||
Output Efficiency | ≥88% | |||||
AC Regulation | THD<3% (linear load) | |||||
DC Voltage | 12V | 24V | 48V | |||
DC Voltage Range | 10-15.5V | 20-31V | 40-61V | |||
Low Voltage Alarm | 10.5±0.5V | 21±0.5V | 42±1V | |||
Low Voltage Shut Down | 10±0.5V | 20±0.5V | 40±1V | |||
Over Voltage Shut Down | 15.5±0.5V | 31±0.5V | 61±1V | |||
Low Voltage Recovery | 13±0.5V | 24±0.5V | 48±1V | |||
Over Voltage Recovery | 14.8±0.5V | 29.5±0.5V | 59±1V | |||
AC Voltage | 120V (±5%) or 230v (±5%) | |||||
USB Outlet | 5V/2.1A | |||||
Working Temp | (-10℃ - +50℃) | |||||
Storage Temp | (-30℃- +70℃) | |||||
Protection | Low Voltage | |||||
Over Voltage | ||||||
Over Load | ||||||
Over Temp | ||||||
Short Circuit | ||||||
Rroduct Size (mm) | 415.7*207*86.5 | |||||
Packing Size (mm) | 460*280*155 | |||||
N.W/G.W (kg) | 4.25/4.9 |
Power inverter AC output part Mosfet/IGBT module exploded
Battery connected oppositely reverse, fuse and Mosfet damage of the inverter
The inverter's buzzer keeps buzzing after being struck by lightning
Inverter can work normally for AGM battery, but damage for lithium battery
Inverter's cooling fan rotates slowly when connected to grid